Characteristics
* Whenever you go out, you don’t have to worry about gas valves anymore.
- Gas Timer locks middle valve, which automatically opens after the use of gas and after the setup time passes,
which makes you feel comfortable while you are out.
* Convenient for everyone.
- Correct use time setup is possible with digital timer.
* ON/OFF button and middle value are adjustable automatically or manually.
- You can open and close with your hands directly like the existing middle valve.
Characteristics of the Product
1. FND DISPLAY Function
- It displays the hour, minute and second by using Digit FND and is excellent in visibility with the use of FND.
- It also displays functional conditions like open and close by ICON and text.
2. One Touch OPEN/CLOSE Function
- If you press POWER switch once while it is on hold, valve moves to OPEN position automatically.
- If you press POWER switch while it is on operation, valve moves to CLOSE position automatically.
3. Safety Function
- The product has a built-in temperature sensor, which not only generates an alarm sound in case of overheating and fire, but also performs automatic valve CLOSE.
- On HOLD mode, it checks the valve condition at regular intervals and, if valve is not closed, it performs
- CLOSE operation.
- On OPERATION mode, if valve is not OPEN, it stops operation and performs automatic valve
- CLOSE operation.
4. Operation Time Setup Function
- On HOLD mode, time is set up by using UP/DOWN switch.
- If you press UP Key once, time increases by the minute, and if you press more than one second, the key operates as a continuous key. The maximum setup time is 9 hours.
- If you press DOWN Key once, time decreases by the minute, and if you press more than one second, the key operates as a continuous key. The minimum setup time is 3 minutes.
5. User Setup Time Function
- On OPERATION Mode, if you press POWER switch for more than 5 seconds, the present time is
saved.
- The saved time is set up as basic operation time when HOLD Mode is switched to OPERATION
Mode by reading the memory automatically.
6. Volume Setup Function
- On HOLD Mode, press both POWER and UP/DOWN button at the same time for more than 5 seconds for volume adjustment.
- To increase the volume, press POWER and UP, and press POWER and DOWN to decrease the volume.
7. Time Remaining Notification Sound Function
- When the remaining time is less than 10 minutes, notification sound of " Bi-big" gis generated every minute.
- When the remaining time is less than 3 minutes, the remaining time blinks by second until the time ends.
8. LOW BATTERY Notification Function
- It checks the battery voltage, and if the voltage is less than the base voltage, Bat is display on FND with melody.
9. Others
- In case the user has moved valve position to OPEN before Mycom checks OPEN/CLOSE
condition at regular intervals through Wake-up, it performs OPERATION mode automatically.
Share K-300 Gastimer in Social Media