High Performance Homecare Ventilator
Using with Single Limb only but possible to control of exhalation PEEP and including of ACV, ACPAP+, and O2 Stream, etc.
- Peak Inspiratory Pressure up to 80cmH2O (above PEEP)
- FiO2 monitoring (real time monitoring)
- Optional SpO2
Wide Application
As respiratory care device, possible to apply for High Flow Therapy as well as ventilation and support. With controlled 80cmH2O pressure, apply to Amyotrophic Lateral Sclerosis (lougehrig)
Transportable Function
- With chargeable battery (Li-ion); Possible to use without external electricity and pressure air
- O2 Blending (air-oxygen mixer) with low flow O2 inlect port and high pressure O2 inelt port
- Pneuma Care: Low Flow O2
- Pneuma 1: Low Flow O2
- Pneuma 2: Low Flow O2 & High Pressure O2
Pneuma Series offer innovated economic and serviceable for maintenance
The Pneuma Series supply economic maintenance with competitive and innovated checking program. The Program is not only for maintenance system but also possible to use of education of ventilation system.
ACPAP+ (Adaptive CPAP Plus Pressure Support)®
[ACPAP+ Function]
It is developed with high technology which applying to the highest class ICU ventilator and applying for a patent. It is innovated reaserch object ‘comfortable breathing’ in CPAP. MEKICS created unique ACPAP+ technology completed the clinical effect and ‘comfortable breathing’ simultaneous.
[Application Model]
Pneuma Series, HFT System, and CPAP Sereis (apply to whole blower type ventilator)
[Principal]
Based on the CPAP, it is contrived to minimize of breaths with difficulty in CPAP as induction of airway open, pressure support that is decreased patient’s effort in inspiration, and active break (rapid pressure interruption) that makes easy of expiration.
[Technology]
It is decreased Ins. Phase Work of Breathing through Ins. Trigger function and Pressure Support function. It makes possible to inhale with small effort of patient (WOB_ins). It is decreased Ex. Phase Work of Breathing through Ex_Sesnse. In this time, interrupt the flow rapidly and supply brk_time (Expiration Break Time). It makes possible to exhale with small effort of patient (WOB_exp) and minimize of breaths with difficulty.
* (brk_time: Expiration Break Time): Application to most convenience respiration pattern
ABiPAP + (Adaptive BiPAP Plus Pressure Support)
ABiPAP+ is taking an Apnea into consideration and adding mandatory respiratory period in ACPAP+.
If makes longer of InpTime in order to use the BiPAP+ together, it is possible to use with spontaneous in upper level.
Benefit of SpO2 Option in Ventilator
Through the SpO2 measurement, recognize the blood oxygen saturation concentration, pulse rate(heart rate), and perfusion index, etc. It makes possible to monitoring of patient breathing both stable and effective. Without extra monitoring, completes an essential respiration management system very simply. Using with EtCO2, can be used more perfectly of Hemo-Dynamic Monitoring function and increases safety of monitoring. The SpO2 module of MEKICS is high performance of low perfusion and the sensor is compatible with Nellcor then it is effective to use the SpO2 sensor by MEKICS
O2 Stream®
Recently the clinical aim of ventilator is minimized of lung injury and recovered of spontaneous respiration. It should be deal with carefully that interrupt ventilation and assistance of breathing in clinically. After weaning by ventilation, happen to use the ventilator (or assistance of breathing) again frequent. That is necessary a method for proper and effective assistance of breathing.
The High Flow Therapy is suitable device for the method and it is contrived by principal that makes sufficient ventilation in the nasal cavity and upper airway. In this aspect, it is different from Nasal CPAP. This function is using with Nasal Cannular was contrived specially and humidifier.
Share MTV1000 PneumaCare in Social Media