Hydraulic solenoid valve
MODEL : PGS series
These solenoid valve series can control not only the direction but the pressure, flow rate in one manifold as an integrated function. These series are realized multi-functions and shock absorber mechanism, and up-dated hydraulic system. Also these series are suited for two or more single -acting cylinders and double-acting cylinders.
Power supply use the one among the AC 110V, 220V, DC12V, 24V safely.
It can be supplied a damper in option to reduce the pulsation.
(1) The characteristic
a) Most simplified hydraulic circuits.
b) Compact, anti-shock, lightweight structure.
c) Easy installation
Features: It can supply the constant pressure to cylinders so that it can works very smoothly dental chair or operating table, etc.
Spec: operating pressure range : 6MPa
(2) Solenoid valve specifications
Description
Unit
PGS-200 x 1 P
PGS-200 x 2 P
PGS-200 x 4 P
PGS-200
x 6 P
PGS-200
x 8 P
Voltage
V
AC110, 220 / DC12, 24
Max. operating pressure
MPa
psi
6
853
6
853
6
853
6
853
6
853
Watt / AC
/ DC
W
19~13
15
19~13
15
19~13
15
19~13
15
19~13
15
Orifice Dia.
mm
1.2
1.2
1.2
1.2
1.2
Rated time
110V AC
220V AC
DC12 / 24V
min
1
10
1
1
10
1
1
10
1
1
10
1
1
10
1
Frequency
Hz
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
Weight
Kg /lbs
0.2 / 0.4
0.5 / 1.1
0.8 / 1.8
1.3 / 2.9
1.7 / 3.7
Dimension
mm
30 x 42 x 65
41x 65 x 71
73 x 65 x
71
105x65x71
137x65x71
(3) The kinds of solenoid valve
(4) How to Use PGS Series Solenoid Valve
1.Caution
These PGS series are precision units and require handling carefully.
If this unit drops during the transportation, it can be caused a trouble in inner parts.
Therefore, please check a package condition when you received this product.
2.Power supply
Please check the related voltage and incorrect voltage may cause fire.
Be careful that continuous operation longer than 10 minutes may burn the coil.
3.Hydraulic oil
a) Use the pure, anti-wear hydraulic oil with viscosity of ISO vg32 grade or equivalent.
b) The material of oil seal is NBR(nitrile budadiene rubber) and do not use it which was
installed. It must cause failure or trouble.
c) It is recommended to replace the hydraulic oil with a new one yearly, but replacing period may
depend on operation conditions in local site.
d) Recommended purity : NAS 8 ~ 9 grade.
e) Recommended temperature : 10 ~ 40?(50 ~104?)
4.Installation method
It is necessary M5 bolt to install in the related equipments.
5.Before operation
a) Before the initial operating, check whether cable wiring, power voltage meet
as specifications or not.
b) Confirm that the piping , other fittings are correct.
(5) Application equipments
(6) Hydraulic circuits of PGS-6P
The PGS-200 x 6P, 3 single-acting cylinders, may be used to control one single-acting cylinder and one double-acting cylinder as below;
Cylinder
Movement
Motor pump
SV1
SV2
SV3
SV4
SV5
SV6
Single-
acting
UP
ON
ON
OFF
OFF
OFF
OFF
OFF
DOWN
OFF
OFF
ON
OFF
OFF
OFF
OFF
Double-
acting
UP
ON
OFF
OFF
ON
OFF
OFF
ON
DOWN
ON
OFF
OFF
OFF
ON
ON
OFF