B. Specification
1) Display : 12.1" Color TFT LCD 2) Resolution : Color LCD : 800*600 3) Trace line : 8 wave form max 4) Trend : HR, SpO2, NIBP, Temp. 5) Vital sign graphic : HR, Spo2, NIBP,Temp.
1) Heart rate and alarm limit. 2) SpO2 percentage and alarm limit. 3) Non-invasive Blood pressure. 4) Temperature. 5) Trend of HR or the Vital signs, Value & Time. 6) Name, Bed ID, Date & time and menu information. 7) Event massage.
1) Channel : 3 channels 2) Electrode : 3 or 5 electrode 3) Lead : 7 Lead (I, II, III, aVR, aVL, aVF) selective 4) Dynamic range : 10mV 5) Heart rate : 20 ~ 300bpm 6) Accuracy : +/-2 % 7) Input signal range : +/- 0.5mV ~ +/- 5mV 8) Defibrillator protection: Defibrillator discharge : 〈5s Defibrillator Artifact recovery time : 〈8s 9) Pacemaker detection mode: User available 10) ST Level measurement : User available 11) Arrhythmia analysis : - Pacemaker detection - 3 Type Arrhythmia (ASY., V-TAC., V-FIB.) - ST
1) Range : 0~100% 2) Accuracy : Adult (+/-2%. for readings 70~100%) (+/-3%. for readings 50~69%) Neonate (+/-3%. for readings 70~95%) (Unspecified 0~49%) 3) Wave out time : 2sec
1) Measurement range : 0~300 mmHg 2) Auto defleation pressure 3) Adult : 300 mmHg 4) Neonate : 150 mmHg 5) Measurement time : max 40 sec.
1) Sensor : YSI 400 series (Optional) 2) Resolution : 0.2°C 3) Measurement range : 0~50°C 4) Accuracy : +/-0.2°C (15~34°C, 41~45°C) +/-0.2°C (34~41°C)
1) ECG Heart rate : High limet (30~300bpm) Low limet (20~290bpm) 2) Spo2 : High saturation (52~100%, 2% Interval (default=off) Low saturation (0~99%, 2% Interval (default=79%) 3) Temperature : High limit (20~50℃) Low limit (10~40℃) 4) NIBP : Systolic High & Low limit (40~300/20~290) 5mmHg Interval Diastolic High & Low limit (20~290/20~280) 5mmHg Interval Mean High & Low limit (35~295/25~285) 5mmHg Interval 5) Alarm on/off : All parameters on/off selective independently. 6) Alarm slience : 30sec
1) Power Input : 15V/3A , +/- 10% external power input 2) Power consumption : 45 watt max.
1) Battery : 12V / 2Ah - Continous operating time : 2Hr (max) (Variable for selected functions) Full Charge Time : 6 hour C. Composition
D. Remark
|
Patient Monitor
Description
Product Inquiry
Purchase Product Catalog
Payment & Shipping Conditions:
- Payment: We accept payment through Paypal Only.
- Shipping: We will ship the catalog once the payment is received. And you will be receiving the catalog with in 10 -14 busines days. Shipping might be delayed in due to international shipping conditions which is depends on the countries receiveing. In case hard copy of catalog is not available then we will ship the soft copy.
- Refund: We can refund the order before shipping process was initiated. Incase Catalog not available, we will make sure to refund the order.
- Note: This is a Catalog Produt.
Share Patient Monitor in Social Media