The hood equipment system of the bath patented by J-E TECH was applied to capture the pollutants generated in the zinc plating process. The main features of this product is to separate the treatment bath and outside air by installing an air-blocking baffle and then prevent the pollutants from exhausting into air by creating a negative pressure inside the baffle with a burial-type hood duct.
1. Problems of the Existing Hood Molten Zinc Plating Bath Application Of the Fan-Suction Hood
- Designing without the Consideration of the Width of the Plating Bath.
- Difficult to Capture Diffused Pollutants.
- Application of Push-Pull Hood.
- Difficult to Design(Design Method based on Experience), used early in Japan.
- Difficult to Harmonize PUSH and Pull.
2.Capture Method of J-E TECH Hood of Molten Zinc Plating Bath Double-Fan Suction
- Capture Efficiency over 95%.
- Capture Efficiency of over 95%.
- Effect of Blocking Outside Air and Exclusive Capture of Pollutants.
Burial of Hood Dust
- The Problem of Damage Solved.
- Semi-Permanent.
- Maximization of Baffle Effect.
Consideration of Operations Safety
- Linkage of Baffle and Safety Guardrail.
Changes of Collection Method
- Extension of Filter Bag Longevity :2.5 times the Existing One Working Efficiency Improvement by 30%.