Intoduction
Solid Insulation Distribution Transformer(SIDT) represents a major advancement in technology, featuring high short circuit resistance, maintenance-free exterior polymer shell, dielectric system and improvements in operating safety. SIDT is designed for sub-surface installations and high and low voltage connections are thus
-
Dong-A single bushing transformers(Model:KSC4306)are manufactured in three type as conventional type,completely self-protected(CSP)type according to the distribution system, the transformers may have two high voltage bushing or single high voltage bushings.
We are adopting the wound type core,no-load loss and excting current will be extremly low
-
Introduction
Overall Dimension and Characteristic
? 1F 13,200V / 22,900GrdY-230V, 60Hz
Capacity
(kVA)
No-load Current
(%)
Voltage Regulation
(%)
No-load Loss
(W)
Efficiency(%)
Dimensions(mm)
Total
-
Transformer Diagnostics Monitor
Introduction
Integrated diagnostic monitoring system on 110~330kV transformer insulation condition
Very easy to integrate it into existing protection systems
Monitors bushing insulation based on the sum of currents method
Monitors PD caused by bushing and transformer insulation defects
Monitors load
-
Introduction
Overall Dimension and Characteristic
? 1F 13,200V / 22,900GrdY-230V, 60Hz
Capacity(kVA)
No-load Current(%)
Voltage Regulation(%)
No-load Loss(W)
Efficiency(%)
Dimensions(mm)
Total
-
Transformer Division
?Pole Mounted Type
?Distribution Transformers
?Power Transformers
?Wind Power/Solar Energy
?Special Purpose Transformers
CT/PT Division
?B.C.T. for Transformers
?B.C.T. for HV Circuit Breakers
?Current Transformers
?Potential
-
Introduction
Standard Type Pad Mounted Transformer has a structure which is suitable for using the downtown, school, factory area where the electricity is transmitted by the underground cable.
It is safe because of no external exposure of power part and it is produced as a structure which is able to attach protective device to the primary, the
-
Roll Former V-115 conbined PE Foam
[ Specification]
Dimension
L12000*W1760*H1830
Weight
About 12000KG
Power
15KW*380V*60HZ (main frame)
Station
24pass
Design Type
All Forming
Capacity
0.5t 18m/min P/E Foam
-
Introduction
Standard Spec.
Standard of application
Regulation(High efficiency energy using appliance)
or IEC 60076 Power Transformer
Frequency
60Hz
Classification of Insulation
Oil temperature : 60? / Winding temperature : 65?
Temperature rising of winding
High Voltage :
-
Roll Former
[Specification]
Dimension
L10000*W1760*H1830
Weight
About 15,000KG
Power
7.5KW*2EA*380V*60HZ 3KW*1EA (Unit)
Station
20 Pass * 2
Design Type
Center Forming
Capacity
0.5t , 18m/min
-
Introduction
? Low Loss (Over 75 % reduction in case of no-load loss)
? Excellent disaster prevention characteristic with molded winding of high-degree vacuum
? Miniaturization with the rectangular type winding
2. Standard Spec.
Standard Spec.
Frequency
60Hz
Classification of Insulation
High
-
Product overview and produced items:The power transformer is widely used in power circuits and the product types and induced cores are different depending on commercial and high frequencies and usages like communication.
The production and supply are done tailor-made and the items are as follows:
> Power Transformer
> Reactor
> Choke Coil
>
-
??????
2011/10/31
???
?????
???
PELLET FORMER,Pelletizing,Used PELLET FORMER,Used Pelletizing
????
2318000 - 0024
??
?? ? ??
150HP
??
??
1
????
???
USA
???
TITAN
Serial No.
????
???
????
????
????
-
Transformer Gas Analyzer Series, TGA-6 / TGA-8
Introduction
Oil chromatogram on-line monitoring system for oil-immersed transformers
Precise instrument integrating with control, measurement and analysis technologies
Can detect the concentrations of all gases dissolved in insulating oil: Hydrogen (H2), Carbon monoxide (CO), Methane (CH4),
-
Pole Mounted type Transformer
Ratings
kVA : 10 to 167
High Voltage : 11000 to 34400 Grd Y
Low Voltage : 105/210V, 230/460V, 4800V and below
Cycle : 50 / 60Hz
Tap : with or without taps
CSP type Pole Transformer
Ratings
kVA : 5 to 167
High Voltage : 11000 to 34400 Grd Y
Low Voltage : 105/210V, 230/460V,
-
The protection relay panel functions restraining from spread of accident when the electric power equipment and power lines is demaged.
The design and manufacturing of protection relay panel is applied as considering application field and
protection method.
So,the reliability of protection relay is obtained.
We provide and produce product
-
Overview of the constant voltage transformer unit (CVT)
It saturates the second iron cores in the transformer due to residual currents from the leaked reactance and condenser by combining the condenser at the output terminal and leaked ferroresonant transformer and improve the power by generating constant output voltage against fluctuation on
-
The transformer of a large capacity coefficient is necessary for the factory having industrial facilities with electric power transmission, and for the home environment needing electric power. As these transformer cut down expenses of operating and the electric loss through the new technical development according to low noise,loss and
-
Introduction
·Plug in termination
·Cubicle welded enclosure
Standard Spec.
Standard Spec.
Rated voltage(kV)
24
Rated Current(A)
2,000
Rated Frequency(Hz)
50 / 60
Rated short time Current(kA/s)
25
Rated power frequency voltage(kV)
70
Rated impulse
-
The transformer of a large capacity coefficient is necessary for the factory having industrial facilities with electric power transmission, and for the home environment needing electric power. As these transformer cut down expenses of operating and the electric loss through the new technical development according to low noise,loss and