Full Face Masks Flame Resistance Tester is test when full face mask’s class 2,3 (follow up KIF’s standard) is exposed on the flame, check for either burn on the parts of full face mask or keep burn over 5 second after without
-
FESTEC’s 3 Meter Smoke Density Tester is the testing equipment measuring the smoke generated when the cable or optical cable is placed horizontally and burn under definite fire resource in the specified condition (3m3 chamber required by IEC61034). This equipment is important to measure the smoke generation from the evalue of light source
-
Hot wire coil ignition tester measures the specimen’s ignition time during hot coil is heated electrically. After heating the specimen that flows electricity by rolling it with hot coil which produces 0.25 ~ 0.27W/? linear power density to 120 seconds, this equipment records the time it is
-
This surface of the material spread flame tester (ISO 9239, Flooring Radiant Panel Tester) is test method that formal reflected spread of flame on flooring material back-draft condition when fire on building happened flame at compartment or room adjacent, or high temperature gas radiated to flooring surface a hot radiation heat accumulated at
-
Portable Test Equipment AIS Compact is designed for on-site application with its maximized portability based on AIS3000 model. AIS Compact features 50% less weight and size with enhanced its functionality for easy measurement of residual stress and tensile properties on-site. When the wireless communication module, UMPC and light weight battery
-
This test method covers the determination of the lower and upper concentration limits of flammability of chemicals having sufficient vapor pressure to form flammable mixtures in air at atmospheric pressure at the test temperature. This test method may be used to determine these limits in the presence of inert dilution gases. No oxidant stronger
-
45 Degree is used to evaluate compliance of fire-retardant products with fireretardant performance standards according to the combustion method, and measures combustion characteristics such as After Glow and After Flame of test specimen installed at a 45-degree angle.
FESTEC 45°Flammability tests After Flame Time and After Glow Time of specimen
-
The specimen can be placed on the Micro Positioning system for convenient operation, and sufficient space is secured under the base to facilitate change of specimen. And also, it allows you to move precisely not only uniaxial but also double axis(X-Y), unlike other existing uniaxial testing unit, AIS3000 main unit which does not have horizontal
-
HCF-NEK606 is an equipment that can decide whether power lines or control lines used in the coast, ships and refineries are resistant to high heat that may be caused by oil or
-
IMO is used to evaluate combustion characteristics of building materials and ship materials and measures spread rate of flame, flame for ignition by distances, CFE (Critical Flux at Extinguishment) and total heat release. This test method is originated from ISO 5658-2 (Reaction to fire tests–Spread of flame- Part 2 Lateral spread on building
-
NANO-AIS Hardware
*Non-destructive Tensile property evaluation for Nano scale material
*Laboratory type IIT system (Automatic test module)
*Piezo actuation system with Non-contact Capacitance sensor
*Jog Shuttle function for remote control and 3-Axis stage operation
*Temperature sensor
*Soundproof system(option)
*Isothermal-isohumidity
-
This equipment virtually simulates an external fire to evaluate the resistance of the roof and other physical elements of fire, in order to qualify for the flame spread experiments (A~C class), in case of A 1.82m, B 2.4m and C 3.9m. It is equipment to displacement of the testing material and the exposure and falling of the roof
-
Erosion Tracking Tester measures the resistance to tracking and erosion by using liquid pollutants and inclined plane specimens. This tester can be evaluated resistance to tracking and erosion of electrical insulation materials used under severe ambient conditions and has two kinds type test way which are constant tracking voltage and stepwise
-
AIT-U Hardware
*Non-destructive Tensile property evaluation
*Laboratory type IIT system (Automatic test module)
*LCD Touch Panel(outer input device attachable for requirements)
*Laser distance measurement
*Self calibration
*LED lightning
*Automatic Moving System
*Jog Shuttle function for remote control and 3-Axis stage
-
The Radiant Panel Flame Spread Tester is an equipment using gas ignited Radiant heat panel to test the surface combustibility of Building product (ASTM E 162) and cellular plastics (ASTM E 3675), Radiant Panel Index (Is) is measured by the flame radio-waves, Critical Heat Flux,(CHF) and Heat Release
-
FESTEC’s BS 6387 Tester, BS 6386 standard is belong to British, is a testing device that checks for the standard level of current in the cable, and also checks the cable’s resistance for heat and water of the
-
SURFACE DEFECTS IN ARTICLE BY AEROSOL METHOD
Features: 1. CAN PRODUCTS
2. NOT DECAYS ANY TESTED MATERIAL
Spec: 450 ML / CAN 6 CANS / BOX
we can develop any products clients need.
If you have any question about our products, request for tell us anytime.
We will always welcome you opening the door
-
It is a heat (radiant heat) flux tester of limited window or fire-retardant door to prevent spread of fire and to secure exit path near the window or fire-retardant door.
This tester is used to allow heat radiation test for supplementing fire protection test of windows in Grade A, Grade B, and Grade F compartment for ships specified in FTP Code
-
FESTEC’s IEC 60331-12 tester is used in test conditions where the basic flame temperature is at
least 830? and tests the cable exposed to flame and mechanical shock that needs to maintain
the circuit
-
This system consists of
- control console
- rate table system
- gyro positioning system
- prequency response