FESTEC’s IEC 60754-1&2 Tester measures gas volume of Halogen Acid (IEC 60754-1), pH
concentration(PH Meter, Hydrogen ions, IEC 60754-2), Conductivity(IEC 60754-2) and etc from a
wire (cable) by radiant heat in the Tube Furnace (IEC 60754-1: 800°c, IEC 60754-2: 950°c)
Especially, FESTEC’s IEC 60754-1&2 is enable to test both IEC 60754-1
-
=Digital Pocket Dissolved Oxygen Tester DMT-50=
Finally it is available, a pocket dissolved oxygen tester, allowing fast and quick measurement of DO in any water source, great for aquaculture, aerobic bacteria respiration measurement, a must for
-
FESTEC’s ISO 5659 is to measure and observe shape of test specimen by radiation heat of Conical Heater, and measures ignition time and mass loss rate.
FESTEC’s ISO 5659 Assembly Tester is an optimal equipment for measuring and observing ignition time and mass loss rate of test specimen as well as shape of test specimen by radiation heat in
-
FESTEC’s Single Vertical Flame Spread Tester is included in IEC 60332-1, IEC 60695-2-4-0 & 1 standards. This test use for method requires a set volume Chamber in standardized for source of ignition in electrical or optical, make stand straight of wires or cables vertically for the vertical arrange flame spread of the
-
=Digital Pocket pH Tester DMT-30=
The pocket pH tester is an inexpensive tester with easy to operate and replaceable electrode.It is ideal for fish farm, environmental plants, industrial water processing and education
-
Thermal Radiation Resistance Tester of full face mask measures exposure radiation from radiation heat resource and evaluates leakage of mask and either valve works or
-
FESTEC’s Bunched Cable Vertical Flame Spread Tester is a series conforming to IEC 60332-3-10, KS C IEC 60332-3-21~25 (Category A~D) standards. The test measures the expansion of vertical flame to the electronically or optically vertical cable or wire using the standard ignition source while supplying a certain amount of air to a chamber of a
-
=Digital Pocket ORP Tester DMT-40=
The pocket ORP tester is an inexpensive pocket type tester which is simple to operate ideal for monitor ozone system, Aquarium & Aquaculture monitoring, Water purification & Drinking Water, Water pollution
-
Full Face Masks Flame Resistance Tester is test when full face mask’s class 2,3 (follow up KIF’s standard) is exposed on the flame, check for either burn on the parts of full face mask or keep burn over 5 second after without
-
FESTEC’s 3 Meter Smoke Density Tester is the testing equipment measuring the smoke generated when the cable or optical cable is placed horizontally and burn under definite fire resource in the specified condition (3m3 chamber required by IEC61034). This equipment is important to measure the smoke generation from the evalue of light source
-
Hot wire coil ignition tester measures the specimen’s ignition time during hot coil is heated electrically. After heating the specimen that flows electricity by rolling it with hot coil which produces 0.25 ~ 0.27W/? linear power density to 120 seconds, this equipment records the time it is
-
This surface of the material spread flame tester (ISO 9239, Flooring Radiant Panel Tester) is test method that formal reflected spread of flame on flooring material back-draft condition when fire on building happened flame at compartment or room adjacent, or high temperature gas radiated to flooring surface a hot radiation heat accumulated at
-
Portable Test Equipment AIS Compact is designed for on-site application with its maximized portability based on AIS3000 model. AIS Compact features 50% less weight and size with enhanced its functionality for easy measurement of residual stress and tensile properties on-site. When the wireless communication module, UMPC and light weight battery
-
This test method covers the determination of the lower and upper concentration limits of flammability of chemicals having sufficient vapor pressure to form flammable mixtures in air at atmospheric pressure at the test temperature. This test method may be used to determine these limits in the presence of inert dilution gases. No oxidant stronger
-
45 Degree is used to evaluate compliance of fire-retardant products with fireretardant performance standards according to the combustion method, and measures combustion characteristics such as After Glow and After Flame of test specimen installed at a 45-degree angle.
FESTEC 45°Flammability tests After Flame Time and After Glow Time of specimen
-
The specimen can be placed on the Micro Positioning system for convenient operation, and sufficient space is secured under the base to facilitate change of specimen. And also, it allows you to move precisely not only uniaxial but also double axis(X-Y), unlike other existing uniaxial testing unit, AIS3000 main unit which does not have horizontal
-
HCF-NEK606 is an equipment that can decide whether power lines or control lines used in the coast, ships and refineries are resistant to high heat that may be caused by oil or
-
IMO is used to evaluate combustion characteristics of building materials and ship materials and measures spread rate of flame, flame for ignition by distances, CFE (Critical Flux at Extinguishment) and total heat release. This test method is originated from ISO 5658-2 (Reaction to fire tests–Spread of flame- Part 2 Lateral spread on building
-
NANO-AIS Hardware
*Non-destructive Tensile property evaluation for Nano scale material
*Laboratory type IIT system (Automatic test module)
*Piezo actuation system with Non-contact Capacitance sensor
*Jog Shuttle function for remote control and 3-Axis stage operation
*Temperature sensor
*Soundproof system(option)
*Isothermal-isohumidity
-
This equipment virtually simulates an external fire to evaluate the resistance of the roof and other physical elements of fire, in order to qualify for the flame spread experiments (A~C class), in case of A 1.82m, B 2.4m and C 3.9m. It is equipment to displacement of the testing material and the exposure and falling of the roof