It is a heat (radiant heat) flux tester of limited window or fire-retardant door to prevent spread of fire and to secure exit path near the window or fire-retardant door.
This tester is used to allow heat radiation test for supplementing fire protection test of windows in Grade A, Grade B, and Grade F compartment for ships specified in FTP Code
-
FESTEC’s IEC 60331-12 tester is used in test conditions where the basic flame temperature is at
least 830? and tests the cable exposed to flame and mechanical shock that needs to maintain
the circuit
-
Introduction
thickness(mm)
50
75
100
125
150
200
length
weigh(kg/ )
9.73
10.61
11.49
12.37
13.25
15.01
length of portable
*Panell Color : B02-Blue ,BR3-Blue , G28-Green , N52-Gray , N65-Gray , O11-Orange, R-99
*Panell Printer Color : 5032 , 5035 ,
-
Introduction
- Classified as Flame Retardant Category A Type called F,A by following Jishihee 3410 of Japan.
? Mainly used for the electric cables of ocean going vessels.
? If it is burnt by one thread when testing, it burns like a sheet of paper but it blocks moisture to become ash during oxygen tests after joining with the cables and
-
FESTEC’s Building Construction Fire Resistance Tester measures the performance of construction material against standard fire conditions, and satisfies the general requirements, vertical history section material, vertical non-history section material and the fire-proof door’s fire proof testing.@ This equipment tests about the walls, doors,
-
FESTEC’s IEC 60331-11 tester is used in test conditions where the basic flame temperature is at least 750? and tests the cable exposed to the flame that needs to maintain the circuit
-
Introduction
thickness(mm)
50
75
100
125
150
200
length
weigh(kg/ )
9.05
10.23
11.11
11.99
12.87
14.63
length of portable
*Panell Color : E02-Blue , BR3-Blue , G28-Green , Ec6-Beige , N52-Gray , N65-Gray
-
Introduction
- Made of less inflammable polypropylene resin mixed with F,R flame retardant agent and its oxygen index is more than 30%.
? Combusting time is measured by setting the test piece at right angle with the flame at the place of no ventilation and it shall satisfy the requirements of the Fire Act; however, the flame should dissipate
-
FESTEC’s Fire Resistance Assemblies Tester is included in both the IEEE 1202 and IEEE 383 standards. This test method is proceed in a chamber with a set volume for 20 minutes. During the 20 minutes, a sample cable is ignited with theoretically 20kW(70,000Btu/hr) flame using an ignition source fixed in a vertical position. This equipment
-
FESTEC’s IEC 60754-1&2 Tester measures gas volume of Halogen Acid (IEC 60754-1), pH
concentration(PH Meter, Hydrogen ions, IEC 60754-2), Conductivity(IEC 60754-2) and etc from a
wire (cable) by radiant heat in the Tube Furnace (IEC 60754-1: 800°c, IEC 60754-2: 950°c)
Especially, FESTEC’s IEC 60754-1&2 is enable to test both IEC 60754-1
-
Introduction
thickness(mm)
50
75
100
125
150
200
length
weigh(kg/ )
9.05
9.93
10.81
11.69
12.57
14.33
length of portable
*Panell Color : Ec6-beige , N52-Gray , N65-Gray , G42-Green , WD2-White
*Panell Printer Color : 3123 , 3141 , Mable/White ,
-
FESTEC’s ISO 5659 is to measure and observe shape of test specimen by radiation heat of Conical Heater, and measures ignition time and mass loss rate.
FESTEC’s ISO 5659 Assembly Tester is an optimal equipment for measuring and observing ignition time and mass loss rate of test specimen as well as shape of test specimen by radiation heat in
-
FESTEC’s Single Vertical Flame Spread Tester is included in IEC 60332-1, IEC 60695-2-4-0 & 1 standards. This test use for method requires a set volume Chamber in standardized for source of ignition in electrical or optical, make stand straight of wires or cables vertically for the vertical arrange flame spread of the
-
1TON MINI CRANE
FIRE FIGHTING DEVICES
On top of price and quality, we’re ready to provide you with customer tailored service that best suits your needs and taste. You can trust on our solid system and rapid work process that will respond to your initial inquiries real-time and ensure optical shipment wherever you are for your utmost
-
Thermal Radiation Resistance Tester of full face mask measures exposure radiation from radiation heat resource and evaluates leakage of mask and either valve works or
-
FESTEC’s Bunched Cable Vertical Flame Spread Tester is a series conforming to IEC 60332-3-10, KS C IEC 60332-3-21~25 (Category A~D) standards. The test measures the expansion of vertical flame to the electronically or optically vertical cable or wire using the standard ignition source while supplying a certain amount of air to a chamber of a
-
Introduction
For early fire action - Portable Aersol Type Fire Extinguisher
Anybody can use
-Easy & simple type! Everyone can use it easily
Spray Distance
-max 5m
-Children can use it
Echo-friendly
-Harmlessness for the human body
Handy,deposit,convenient
-It’s small spray type so it is convenient for deposit and
-
Full Face Masks Flame Resistance Tester is test when full face mask’s class 2,3 (follow up KIF’s standard) is exposed on the flame, check for either burn on the parts of full face mask or keep burn over 5 second after without
-
SH-5000 Single opening type sliding door is an automatic door suitable for entrances to federal buildings, unmanned guard systems for apartment building and automatic door to factories. It is designed to fully open in an emergency situation, such as fire, so that a large traffic of people being evacuated or a large-sized cargo can pass through the
-
FESTEC’s 3 Meter Smoke Density Tester is the testing equipment measuring the smoke generated when the cable or optical cable is placed horizontally and burn under definite fire resource in the specified condition (3m3 chamber required by IEC61034). This equipment is important to measure the smoke generation from the evalue of light source